Washing Machine - Motor Run Capacitor

  • Capacitors used in washing machines are typically motor run capacitors, which are designed to help start and run the motor efficiently.
  • These capacitors are usually rated for continuous duty and are designed to handle the high current demands of the washing machine motor.
  • If you have a specific washing machine model in mind, it’s best to refer to the manufacturer’s specifications for the exact type and rating of the capacitor used.
  • Washing Machine has two motors for separate functions each with its own capacitor.
  • These two capacitors are nowadays housed in one casing ,with 4 terminals .

CONSTRUCTION:

  • Metallized polypropylene film
  • Plastic can and Plastic top
  • Aluminum case with metal top
  • Filling material: PU Resin

TYPICAL APPLICATIONS:

  • For general sine wave application, mainly as motor run

MOUNTING PARTS:

  • Special design of Plastic can for fitment also available.

FEATURES:

  • Self-healing properties
  • Low dissipation factor
  • S0/P0/S2/S3 safety class
  • High insulation resistance

TERMINALS :

  • 2 Terminal - Wire Type Flexible Lead
  • 4 Terminal - Wire Type Flexible Lead
  • Others on request

APPROVALS:

  • TECHNICAL SPECIFICATIONS

    Reference Standard
    IEC 60252 ; IS 2993 ; UL 810Safety class to IEC 60252-1:2010
    S0 / P0Life expectancy to IEC 60252-1:2010/AMD1:2013
    450 V : 10000 h (Class B / Class C)UL 810
    Approved componentRated capacitance CR
    (5.3+2) uF to uFTolerance Tx
    ± 5%Rated voltage Vrms
    450 V AC, others on requestRated frequency fR
    50/60 Hz

    Electrical Test

    AC test voltage terminal to terminal VTT, rel.
    2.0 X VR, 2 s (routine test)AC test voltage terminal to can VTC
    3000 V AC, 2 s (routine test)Insulation resistance Rins or time constant at 20 °C Humidity ≤ 65% (minimum as-delivered
    values)
    10000 OhmsDissipation factor tan δ at 20 °C
    ≤ 2 x 10-3 (1 kHz)Maximum rate of voltage rise dV/dt
    max 10 V/ µs

    Climatic Data

    Climatic Category
    40/85/21Lower category Tmin
    –40° CUpper category Tmax
    +70/85° CDamp heat test
    21 days

     

    C (µF) ± 5%Dimensions L x B x H (mm)1.50-4.0028×524.00-8.0030/35 x 548.00-10.035 x 60

N-MRC SERIES